ICU VENTILATOR V-8800 ORICARE

V8800 is a critical care ventilator for infants, children and adults. It has comprehensive functionality, a user-friendly design, and is full of high-quality, reliable treatment options for the clinician. Complete ventilation functionality: In addition to typical ventilation modes, V8800 also has BIVENT and PRVC, to fully meet the demands of critical care mechanical ventilation.V8800 also includes enhanced features such as automatic tube compensation as part of the standard configuration.V8800 includes NIV Ventilation as a standard feature. Users have the flexibility to use V8800 for both invasive and non-invasive therapy to reduce equipment costs.V8800 is full of valuable clinical features: Synchronized nebulizer Inspiratory and expiratory hold Manual inspiration Smart suction.

Product Information

Standard Configuration:

Patient Age Group Pediatric, Adult
Tidal Volume 20 to 2500 ml
Ventilation Mode PCV, PRVC, SIMV (VCV) + PSV, SIMV (PCV) + PSV, SIMV (PRVC) + PSV, SPONT/CPAP + PSV (BIVENT/APRV) + PSV, NIV/CPAP + PSV, NIV/PCV, VCV
Respiratory Rate 1 to 120 bpm

Optional Enhancements

Graphic Screen Yes
Nurse Call Yes
Pressure Values Pmin, Pplat, Pmean, Ppeak, PEEP, Volume/Flow values: VTI, VTE, MV, MVspont, Leak%

Monitoring

FiO2 Yes

Parameter

PEEP/CPAP 0-50 cm H2O, 2-20 cm H2O
Inspiratory Time 0.2 – 9 sec
Inspiratory Pause Time 0-4 sec
Pinsp USA: 5-90 cm H2O, International: 0-100 cm H2O
Tslope 0-2 sec
Nebulizer 30 or 45 minutes
Esens 5%-80%

Graphical Patient Data

Loops Flow – Pressure, Pressure – Volume

Additional Details

Operating Temperature 10 to 40ºC
Power Supply 100 to 240 V, 50 to 60 Hz
Display Size 15 inch
Display Type TFT LCD color screen
Battery Backup 2 hours
FiO2% 21% – 100%
Alarms MV high, MV low, Circuit disconnect, Paw high, Paw low, Continuous airway pressure high, VTi high, fspont high, Tapnea, FiO2 high, FiO2 low, etCO2 high, etCO2 low, Power supply failure, Battery low, Battery exhausted, Air supply failure, O2 supply failure, PEEP low
Dimensions 624 x 774 x1 410 mm
Relative Humidity Non-condensing: 5-95% (Operation), Non-condensing: ≤ 95%(Storage)
Atmospheric Pressure 500 hPa-1060 hPa(Operation & Storage)
Standards UL/IEC 60601-1, IEC 60601-1-2, IEC 60601-2-12, EN 794-1
Gas Supply O2, Air, 200 kPa -650kPa (29-94PSI)
Communication/Interface RS232, VGA, USB, Rj45